Novasina Water activity meter LabStart-AW
- Novasina - LabStart-aw
Novasina LabStart-aw Water Activity Meter for Routine QC Testing
Entry-Level Water Activity Measurement with Proven Novasina Sensor Technology
The Novasina LabStart-aw Water Activity Meter is designed as an accessible starting point for laboratories, food producers and quality-control teams that need dependable water activity measurements without the advanced features and higher accuracy of Novasina's premium systems.
It uses Novasina's proven resistive electrolytic sensor technology and measures over a broad 0.03 to 1.00 aw range. The LabStart-aw is especially suitable for routine measurements in the low-to-medium water activity range where straightforward operation, compact size and economical ownership are priorities.
Why Measure Water Activity?
Water activity describes the energy status or availability of water in a product rather than simply the total quantity of moisture it contains. This distinction is important because available water has a strong influence on microbial stability, chemical reactions and physical product characteristics.
For food, pharmaceutical, cosmetic and related products, monitoring aw can help manufacturers understand product stability, compare formulations and maintain more consistent processing and storage conditions.
Designed as a Practical Starter Instrument
Novasina positions the LabStart-aw as a starter-level water activity meter for users who do not require the tighter accuracy, advanced temperature control or communication functions offered by higher-level instruments.
Its simplified design makes it well suited to routine checks, educational laboratories, product development work and quality-control environments where a straightforward aw measurement is sufficient.
Wide Water Activity Measurement Range
The LabStart-aw measures water activity from 0.03 to 1.00 aw, covering a broad range of products and sample types. Its adjustment range is focused on the lower-to-medium aw region where the instrument is intended to provide its best routine performance.
| Water Activity Specification | LabStart-aw |
|---|---|
| Measurement Principle | Resistive electrolytic |
| Measurement Range | 0.03 - 1.00 aw |
| Calibration / Adjustment Range | 0.33 - 0.75 aw |
| Resolution | 0.01 aw |
| Accuracy | ±0.03 aw within the calibration range |
| Precision | ±0.01 aw within the calibration range |
| Repeatability | ±0.01 aw within the calibration range |
Built-In Temperature Measurement
Because water activity is temperature dependent, the LabStart-aw also monitors sample temperature. The current Novasina specification uses surface infrared and NTC temperature sensing over a 15 to 30°C measurement range.
The instrument does not provide active temperature control, so samples and the instrument should be allowed to stabilize under consistent ambient conditions when comparative or repeat measurements are required.
| Temperature Specification | Value |
|---|---|
| Temperature Measurement | Surface IR and NTC |
| Measurement Range | 15 - 30°C (59 - 86°F) |
| Resolution | 0.1°C |
| Accuracy | ±0.15°C |
| Precision | ±0.1°C |
| Temperature Control | None |
Simple Verification and Calibration
The LabStart-aw supports verification and adjustment using Novasina SAL-T reference standards. The instrument provides calibration points at 33% and 75% relative humidity, allowing routine performance checks within its intended operating range.
The standard package includes a 75% SAL-T reference salt together with a factory calibration certificate.
Compact Bench-Top Design
The instrument uses a compact two-part PC/ABS housing that occupies little bench space. Its measurement chamber accepts 15 ml samples using small 30 mm diameter sample cups, making sample preparation simple and economical.
| Instrument Specification | Value |
|---|---|
| Display | LC display, 35 × 69 mm |
| Measurement Chamber Volume | 15 ml |
| Sample Cup Size | 30 mm diameter × 14 mm high |
| Housing | Two-part PC/ABS |
| Dimensions | 225 × 140 × 85 mm |
| Weight | 1.2 kg |
| Instrument Supply | 5 VDC ±6% |
| Maximum Power Consumption | 10 W |
| Power Supply | 90 - 264 VAC, 50/60 Hz |
| Protection Class | IP22 |
| Communication | None |
| 21 CFR Part 11 | Not compliant |
Key Features
- Entry-level Novasina water activity meter
- Resistive electrolytic aw sensor
- Wide 0.03 to 1.00 aw measurement range
- 0.01 aw resolution
- ±0.03 aw accuracy within the calibration range
- Built-in sample temperature measurement
- Simple operation for routine QC work
- 33% and 75% RH calibration points
- Reusable SAL-T reference standards
- Compact 15 ml measurement chamber
- Small 30 mm sample cups
- Stable bench-top housing
- No PC connection or communications setup required
- Factory calibration certificate supplied
Typical Applications
- Routine food quality-control testing
- Bakery and snack products
- Powders and dry ingredients
- Cereals and grain-based products
- Confectionery
- Pet food
- Pharmaceutical product development
- Cosmetic products
- Educational and training laboratories
- Basic formulation and stability studies
Standard Scope of Supply
- Novasina LabStart-aw water activity meter
- 20 sample cups
- 1 × SAL-T 75% RH reference standard
- Factory calibration certificate
When Is the LabStart-aw the Right Choice?
The LabStart-aw is best suited to users who need a simple and economical water activity meter for routine measurements and do not require temperature control, advanced data logging, PC communication or very high measurement accuracy.
For applications requiring substantially tighter accuracy, automated temperature control, faster testing or electronic data management, a higher-level Novasina instrument such as the LabTouch-aw or LabMaster-aw may be more appropriate.
Q&A
What is the LabStart-aw designed for?
It is designed as an entry-level water activity meter for users beginning routine aw testing or for applications where very high accuracy and advanced instrument features are not required.
What water activity range can it measure?
The LabStart-aw measures from 0.03 to 1.00 aw. Its calibration range is focused on approximately 0.33 to 0.75 aw.
How accurate is the LabStart-aw?
Novasina specifies an accuracy of ±0.03 aw within the calibration range, with precision and repeatability of approximately ±0.01 aw when temperature remains stable.
Does it control sample temperature?
No. The LabStart-aw measures temperature but does not actively control it. For best repeatability, samples and the instrument should be allowed to stabilize under consistent ambient conditions.
How is the instrument calibrated or verified?
The LabStart-aw uses Novasina SAL-T humidity reference standards. The instrument supports 33% and 75% RH calibration points, and a 75% SAL-T reference standard is included with the instrument.
Can it connect to a computer?
No. The LabStart-aw does not provide a communication interface or PC data transfer. It is intended as a simple stand-alone instrument.
What is the difference between the LabStart-aw and LabTouch-aw?
The LabStart-aw is the simpler and more economical instrument. The LabTouch-aw provides substantially higher aw accuracy, finer resolution, semi-thermostatic temperature control, faster measurement functions and electronic data connectivity.
Is the LabStart-aw 21 CFR Part 11 compliant?
No. The manufacturer specifies that the LabStart-aw is not 21 CFR Part 11 compliant. Applications requiring regulated electronic records should therefore use a system specifically designed for that purpose.
What samples can be tested?
The instrument can be used with many products that fit within its small sample cup, including powders, dry foods, bakery products, cereals, confectionery, pharmaceutical materials and cosmetic products, provided the sample is compatible with the sensor and appropriate preparation procedures are followed.
Instrument-Specifications
| Versions | N/A | ||
| Current Supply | 5 VDC, +/-6%, max. power consumption 10W | ||
| Power Supply / Mains | 90……264 VAC 50/60 Hz | ||
| Display | LC-display, dimension: 35x69 mm | ||
| Communication | none | ||
| Housing | Two-part PC/ABS housing, Weight: 1.2kg Dimensions (L x W x H)= 225 x 140 x 85 mm | ||
| Volume measurement chamber | 15mL | ||
| Dimensions Sample Cup | Diameter 30mm x Height 14mm | ||
| Protection Class | IP22 | ||
| 21CFR 11 | Not Compliant | ||
| Price | $USD 2,648.00 |
|---|
Need larger scale equipment for a bigger project?
Our parent site geneq.com works by quote requests, so we can offer a unique price per any combination of items you choose, and the best shipping company/route for weighty items. We distribute the biggest names in the industry since 1972!