Novasina Water activity meter LabTouch CM-2
- Novasina - LabTouch
Fast, Reliable Water Activity Testing for Laboratory and Production Quality Control
Precise Water Activity Measurement with Simple Touch-Screen Operation
The Novasina LabTouch-aw CM-2 Water Activity Meter is designed for accurate routine determination of water activity in food, pharmaceutical, cosmetic and other moisture-sensitive products. It combines Novasina's resistive electrolytic sensor technology with a large 4.3-inch colour touch screen, programmable temperature control and multiple measurement functions in a compact benchtop instrument.
With a water activity measurement range of 0.030 to 1.000 aw, resolution of 0.001 aw and accuracy of ±0.005 aw within the calibration range, the LabTouch is suited to both quality-control laboratories and at-line testing in production environments.
Water Activity Is Different from Moisture Content
Water activity measures the amount of available or “free” water in a product rather than its total water content. The aw value ranges from 0 for an extremely dry condition to 1.000 at the upper end of the water activity scale.
This distinction is important because available water influences microbial stability as well as physical and chemical changes within a product. Two products can contain similar amounts of total moisture while having significantly different water activity values.
CM-2 Measuring Cell for Regular Samples
This LabTouch configuration uses Novasina's CM-2 measuring cell, which is intended for regular samples. Novasina recommends its alternative CM-3 measuring cell when samples contain more than 0.1% ethanol by volume.
The CM-2 uses a resistive electrolytic water activity sensor together with surface infrared and NTC temperature measurement. This combination allows the instrument to monitor both the sample environment and sample surface temperature during testing.
Fast Mode for Routine Testing
For applications where rapid results are important, the LabTouch provides a Fast Mode with results within 10 minutes. This makes the instrument especially useful for routine incoming-material checks, production monitoring and finished-product quality control where waiting for full equilibrium may not always be practical.
Programmable Temperature Control
Water activity is temperature dependent, so controlling measurement conditions improves consistency when comparing results from different samples or testing sessions. The LabTouch provides semi-thermostatic temperature control from 15 to 30°C (59 to 86°F).
The instrument also measures sample surface temperature over a range of 5 to 45°C (41 to 113°F) with 0.1°C resolution.
Designed for Both QC Laboratories and Production Areas
The LabTouch combines laboratory-level measurement performance with straightforward touch-screen operation. Its compact benchtop design makes it suitable for centralized quality-control laboratories as well as installation close to production lines for routine at-line testing.
Typical sample formats include liquids, powders, granulates, pastes, gels and solid products that can be placed in the supplied sample cups and accommodated within the 15 ml measurement chamber.
Key Features
- Water activity measurement range from 0.030 to 1.000 aw
- Accuracy of ±0.005 aw within the calibration range
- Resolution of 0.001 aw
- Repeatability of ±0.002 aw within the calibration range
- Resistive electrolytic water activity sensor
- CM-2 measuring cell for regular samples
- Fast Mode provides results within 10 minutes
- Programmable measurement temperature from 15 to 30°C
- Surface infrared and NTC temperature measurement
- Large 4.3-inch colour touch-screen display
- USB connection for PC communication
- SD/SDHC memory card support
- 15 ml measurement chamber
- Protective sensor filters available for challenging samples
- Compact benchtop design for laboratory or production use
Water Activity Performance
| Specification | LabTouch-aw CM-2 |
|---|---|
| Measurement Principle | Resistive electrolytic |
| Water Activity Range | 0.030 - 1.000 aw |
| Calibration Range | 0.110 - 0.970 aw |
| Resolution | 0.001 aw |
| Accuracy | ±0.005 aw within calibration range |
| Precision | ±0.003 aw within calibration range |
| Repeatability | ±0.002 aw within calibration range |
| Fast Measurement Mode | Results within 10 minutes |
Temperature Measurement & Control
| Specification | Value |
|---|---|
| Temperature Measurement Principle | Surface IR and NTC |
| Temperature Measurement Range | 5 - 45°C (41 - 113°F) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.10°C |
| Temperature Precision | ±0.1°C |
| Programmable Measurement Temperature | 15 - 30°C (59 - 86°F) |
Calibration & Verification
The LabTouch can be checked and adjusted using Novasina reference humidity standards. Available calibration points cover a wide portion of the instrument's operating range, allowing performance to be verified at values relevant to the products being tested.
| Available Calibration Points | Relative Humidity |
|---|---|
| Point 1 | 11% RH |
| Point 2 | 33% RH |
| Point 3 | 53% RH |
| Point 4 | 58% RH |
| Point 5 | 75% RH |
| Point 6 | 84% RH |
| Point 7 | 90% RH |
| Point 8 | 97% RH |
General Specifications
| Specification | Value |
|---|---|
| Display | 4.3" colour LC display |
| Communication | USB for PC communication; SD/SDHC card |
| Measurement Chamber Volume | 15 ml |
| Sample Cup Size | 40 mm diameter × 12 mm high |
| Housing | Two-part PC/ABS housing |
| Dimensions | 200 × 285 × 105 mm |
| Weight | 2.8 kg |
| Instrument Supply | 5 VDC ±6% |
| Maximum Power Consumption | 10 W |
| Power Supply | 90 - 264 VAC, 50/60 Hz |
| Protection Class | IP22 |
Protective Filters for Challenging Samples
Novasina offers optional protective filters for applications involving samples that may release acids, volatile substances or redox-active compounds. Selecting the appropriate filter helps protect the measuring cell when testing more chemically demanding products.
For samples containing more than 0.1% ethanol by volume, Novasina recommends selecting the CM-3 measuring cell rather than the CM-2 configuration.
Typical Applications
- Food product development and quality control
- Bakery and confectionery products
- Meat and processed food products
- Dairy products
- Powders and dry ingredients
- Pharmaceutical products
- Cosmetics and personal-care products
- Incoming ingredient inspection
- Production-line quality checks
- Storage and shelf-life studies
Standard Scope of Supply
- Novasina LabTouch-aw water activity meter
- CM-2 measuring cell configuration
- 40 sample cups
- 4 SAL-T reference humidity standards: 33%, 58%, 75% and 84% RH
- Factory calibration certificate
Why Temperature Stability Matters in Water Activity Testing
Water activity changes with temperature, and temperature differences between the sample and measuring chamber can influence equilibrium and measurement stability. The LabTouch's semi-thermostatic chamber and integrated temperature measurement help create more consistent test conditions, particularly when comparing results over time or between production batches.
Q&A
What is the difference between water activity and moisture content?
Moisture content measures the total amount of water present in a product. Water activity measures how much of that water is available to participate in biological, chemical and physical processes. Products with similar moisture contents can therefore have different aw values and different stability characteristics.
What is the difference between the CM-2 and CM-3 measuring cells?
The CM-2 is intended for regular samples. Novasina recommends the CM-3 measuring cell for samples containing more than 0.1% ethanol by volume because alcohol vapours can interfere with conventional water activity sensors.
How quickly can the LabTouch CM-2 provide a result?
The instrument includes a Fast Mode designed to provide a result within 10 minutes. Actual measurement behaviour can still depend on the sample, temperature and selected measurement method.
Does the LabTouch control sample temperature?
The instrument provides semi-thermostatic heating with a programmable measurement temperature from 15 to 30°C. It also measures sample surface temperature using infrared and NTC temperature sensing.
Can the instrument be calibrated by the user?
Yes. Novasina provides certified SAL-T humidity standards for verification and adjustment at several points between 11% and 97% RH. The LabTouch package includes four reference standards at 33%, 58%, 75% and 84% RH.
Can liquid and solid samples be tested?
Yes. The measurement principle is suitable for many sample forms, including liquids, powders, pastes, gels and solids, provided the sample can be prepared appropriately and placed in the measurement cup without contaminating the sensor.
Can measurement data be transferred to a computer?
Yes. The LabTouch provides USB connectivity for PC communication and also supports SD/SDHC memory cards for data handling.
Is the LabTouch suitable for pharmaceutical quality control?
Yes. Novasina specifically identifies pharmaceutical products among the intended applications for water activity measurement. Water activity is also addressed in pharmaceutical guidance such as USP <922> and USP <1112>, although users should confirm their own validation and regulatory requirements for a specific quality system.
| Current Supply | 5 VDC, +/-6%, max. power consumption 10W |
| Power Supply / Mains | 90……264 VAC 50/60 Hz |
| Display | 4.3" LC-Display , color |
| Communication | USB for PC / Drucker (Advanced) SD/SDHC-card (Basic and Advanced) |
| Housing | Two-part PC/ABS housing, Weight: 2.8kg Dimensions (L x W x H)= 200 x 285 x 105mm |
| Volume measurement chamber | 15mL |
| Dimensions Sample Cup | Durchmesser 30mm x Höhe 14mm |
| Protection Class | IP22 |
| 21CFR 11 | Partially Compliant |
| Parameter | ||
| Water Activity | Temperature | |
| Measurement Principle | Resistive Electrolytic | Surface-IR and NTC |
| Measurement Range | 0.030……1.000aw | 5……45°C (41……113°F) |
| Calibration Range | 0.110……0.970aw | N/A |
| Resolution | 0.001aw | 0.1°C |
| Accuracy | +/-0.005aw within cal. range | +/-0.15°C |
| Precision | +/-0.003aw within cal. range | +/-0.1°C |
| Repeatability | +/-0.002aw within cal. range | N/A |
| Temperature Control | Programmable measurement temperature in the range of 15……30°C (59……86°F)* | |
| Calibration Points (%rH) | 11%, 33%, 53%, 58%, 75%, 84%, 90%, 97% | |
| Price | $USD 8,711.00 |
|---|
Need larger scale equipment for a bigger project?
Our parent site geneq.com works by quote requests, so we can offer a unique price per any combination of items you choose, and the best shipping company/route for weighty items. We distribute the biggest names in the industry since 1972!