MULTIPARAMETER WATER QUALITY METER (PH / ISE / EC / DO / TURBIDITY)
Hanna MULTIPARAMETER WATER QUALITY METER (PH / ISE / EC / DO / TURBIDITY) for Application-Based Model Selection
Great for routine testing, inspection, and quality-control workflows, where the right choice often depends on differences in configuration, range, portability, and application fit.
The multi-sensor probe based on a microprocessor enables the measurement of essential parameters such as pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe sends readings in a digital format and allows data to be recorded even when not connected to the meter. An optional GPS allows for tracking the location of measurements. Additionally, the entire system is straightforward to install and user-friendly. This versatile multiparameter water meter is fully customizable and comes with all required accessories, enclosed in a sturdy carrying case
- Optional GPS provides location tracking of measurements.
- Color-coded, field-replaceable sensors
- Great for environmental, field, and laboratory testing.
Built-in GPS Receiver
- 12-channel GPS receiver and antenna
- Tracks location using satellites to within 30 feet
- Latitude and longitude recorded with readings
- Location naming for GPS coordinates
- Distance from the current location to the stored location
- HI9829 multiparameter water quality meter software supplied integrates data collected with Google™ maps - Measurement readings including GPS coordinates - Date and time - Named locations and remarks - Sample number
HI9829-MULTIPARAMETER WATER QUALITY METER | PH / ISE / EC / DO / TURBIDITY
Two probes to choose from (Basic or Logging)
The HI7609829 (basic) and HI7629829 (logging) are multiparameter water meter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829 multiparameter water quality meter. By default, the HI9829 and corresponding probe will be supplied with pH/ORP, conductivity, and dissolved oxygen sensors. Therefore, either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.
HI7609829 Basic Probe
- Digital probe that is less than 2 inches in diameter
- 3 color-coded sensor inputs
- IP68 rating for continuous immersion in water
- Multistrand – multiconductor cable rated for 150 lbs (intermittent use)
- Available with 4, 10, or 20-meter cable
- A weighted shield protects all sensors
HI7609829 probe without logging
- HI7629829 Autonomously Logging Probe
- Same as basic probe but with logging capability
- Logs data independent of HI9829 meter
- Operates on 4 “AA” batteries for up to 70 days*
- Stores up to 140,000 single parameter readings or 35,000 for all parameters
- Logs data from 1 second to 3 hours
- Choose to be supplied with EC or EC/Turbidity sensor
- Supplied with a USB cable for direct connection to Windows-compatible PC
*All channels logging at 10-minute intervals with no averaging
Related Products
For complementary water testing instruments, check out the Portable pH Meters for field and lab measurements, the Benchtop Conductivity Meters for precise conductivity testing, or the Eco-Sensors Multiparameter Meters for versatile environmental monitoring.
Color-Coded, Field Replaceable Sensors

Waterproof Protection
The multiparameter water quality meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Backlit Dot Matrix LCD Display

The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Intuitive Keypad
The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help, and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated Help Key
Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Auto-sensor Recognition
The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Product Q&A
What is the HI9829 multiparameter water quality meter used for?
The HI9829 is designed to measure up to 14 water quality parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. It is suitable for environmental, field, and laboratory testing.
What probes are available for the HI9829?
The meter can be paired with the HI7609829 basic probe or the HI7629829 logging probe. Both support pH/ORP, conductivity, and dissolved oxygen sensors, with optional turbidity measurement. The logging probe can record data independently of the meter for up to 70 days.
Does the HI9829 provide location tracking?
Yes, an optional built-in GPS allows recording latitude and longitude for each measurement. Locations can be named, and data integrates with Google™ maps via the supplied software.
What type of display does the meter use?
The HI9829 features a backlit graphic LCD that can show up to 12 parameters simultaneously and supports virtual keys for an intuitive interface.
Is the HI9829 waterproof?
Yes, the meter has an IP67-rated casing and the probe has an IP68 rating for continuous immersion, allowing operation in wet environments.
How is the HI9829 calibrated?
The meter allows quick single-point calibration for pH, conductivity, and dissolved oxygen, with additional standard calibration options for up to three points for pH, one point for conductivity, and two points for dissolved oxygen. GLP data including calibration history is stored and viewable at a touch.
How long does the HI9829 battery last?
It uses four 1.5V “C” NiMH rechargeable batteries, providing up to 140 hours of operation. A battery icon on the display indicates remaining power.
| pH Range | 0.00 to 14.00 pH |
|---|---|
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| mV Range | ±600.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.5 mV |
| ORP Range | ±2000 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±1.0 mV |
| ORP Calibration | automatic at one custom point (relative mV) |
| EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Resolution | Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
| EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
| EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
| TDS Resolution | Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L),Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L),Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
| TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
| TDS Calibration | based on conductivity or salinity calibration |
| Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
| Resistivity Resolution | dependent on resistivity reading |
| Resistivity Calibration | based on conductivity calibration |
| Salinity Range | 0.00 to 70.00 PSU |
| Salinity Resolution | 0.01 PSU |
| Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
| Salinity Calibration | based on conductivity calibration |
| Seawater σ Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
| Seawater σ Resolution | 0.1 σt, σ₀, σ₁₅ |
| Seawater σ Accuracy | ±1 σt, σ₀, σ₁₅ |
| Seawater σ Calibration | based on conductivity or salinity calibration |
| Ammonium-Nitrogen Range | 0.02 to 200.0 ppm Am (as NH4 +-N) |
| Ammonium-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Ammonium-Nitrogen Accuracy | ±5 % reading or 2 ppm |
| Ammonium-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
| Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Chloride Accuracy | ±5 % of reading or 2 ppm |
| Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Nitrate-Nitrogen Range | 0.62 to 200.0 ppm Ni (as NO3 - -N) |
| Nitrate-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
| Nitrate-Nitrogen Accuracy | ±5 % of reading or 2 ppm |
| Nitrate-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
| Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
| Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater |
| Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
| DO Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
| DO Resolution | 0.1%; 0.01 ppm (mg/L) |
| DO Accuracy | 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L),whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading |
| DO Calibration | automatic one or two points at 0 and 100% or one custom point |
| Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
| Atmospheric Pressure Calibration | automatic at one custom point |
| Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
| Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
| Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
| Temperature Calibration | automatic at one custom point |
| Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
| Logging Memory | 44,000 records (continuous logging or log-on-demand of all parameters) |
| Logging Interval | one second to three hours |
| PC Connectivity | USB (with HI 929829 software) |
| Battery Type/Life | 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration |
| Waterproof Protection | IP67 |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
| Weight | 750 g (26.5 oz.) |
| GPS | 12 channel receiver 10 m (30 ft) accuracy |