Portable multiparameter water quality meter for pH, ORP, dissolved oxygen, pressure and temperature
The Hanna Instruments HI98196 is a waterproof portable multiparameter meter designed for water quality measurements in both field and laboratory environments. It measures pH, ORP, dissolved oxygen, atmospheric pressure and temperature using a rugged digital multi-sensor probe, while onboard data logging provides a reliable record of measurements for later review and analysis.
The microprocessor-based HI7698196 probe transmits readings digitally to the meter, helping provide reliable signal transfer even when long probe cables are required. The system combines multiple important water quality measurements in one portable instrument and is designed for straightforward setup, calibration, monitoring and data collection.
Multiparameter water quality measurement
Digital multi-sensor probe
pH, ORP, dissolved oxygen, pressure and temperature
Data logging and USB connectivity
Waterproof meter and probe
The HI98196 is a waterproof portable logging multiparameter meter designed to monitor several key water quality parameters from a single instrument. Its HI7698196 probe supports field-replaceable pH/ORP and dissolved oxygen sensors and includes temperature measurement. The meter also incorporates atmospheric pressure measurement for dissolved oxygen compensation.
The probe connects digitally to the meter, where readings can be viewed, calibrated and logged. The HI98196 can store up to 45,000 continuous or log-on-demand samples, making it useful when measurements must be documented over time rather than recorded only as individual spot readings.
Features at a glance
Backlit Graphic LCD Display - The HI98196 features a backlit graphic LCD with on-screen help and the ability to display multiple measured parameters simultaneously. Virtual soft keys and clearly organized menus help simplify instrument setup, calibration and measurement.
Waterproof Protection - The meter is housed in an IP67-rated waterproof enclosure and can withstand temporary immersion in water. The HI7698196 probe is rated IP68 for continuous immersion, making the system well suited to field water-quality measurements.
Quick Connect Digital Probe - The HI7698196 probe uses a Quick Connect DIN connector to create a secure waterproof connection with the meter. Digital communication between the probe and meter helps maintain reliable data transmission and supports long probe-cable configurations.
Color-Coded, Field-Replaceable Sensors - The probe uses screw-type field-replaceable sensors that are color coded for easier identification. The HI98196 is supplied with the HI7698194-1 pH/ORP sensor and HI7698194-2 galvanic dissolved oxygen sensor.
Automatic Sensor Recognition - The meter and probe automatically recognize connected sensors. Parameters associated with sensors that are not installed are not displayed or made available for configuration.
Automatic Temperature Compensation - The integrated temperature sensor provides temperature measurement and supports automatic temperature compensation for applicable measurements.
Automatic Barometric Pressure Compensation - A built-in barometer provides atmospheric pressure measurement and compensation for dissolved oxygen readings. Pressure can be displayed in user-selectable units.
Flexible Calibration - The instrument provides guided calibration procedures for pH, ORP and dissolved oxygen measurements. Calibration information can be reviewed through the meter's GLP functions.
GLP Data - The HI98196 includes Good Laboratory Practice functions that allow users to review calibration information, including calibration date and time, standards or buffers used and relevant calibration data.
Data Logging - The HI98196 can store up to 45,000 continuous or log-on-demand samples. Logging intervals can be configured for monitoring measurements over time.
Intuitive Keypad - The fitted rubber keypad includes dedicated controls for power, backlight, navigation, help and data entry. Soft keys shown on the display guide users through parameter configuration, meter setup, calibration and logging functions.
Dedicated Help Key - Context-sensitive help is available directly from the meter. On-screen instructions can guide users through setup, calibration and other instrument functions.
PC Connectivity - Logged data can be transferred to a compatible computer through USB using Hanna software and the appropriate USB cable.
Long Battery Life - The HI98196 operates on four 1.5 V AA batteries and provides approximately 360 hours of continuous use without the backlight under specified operating conditions. A battery indicator on the display shows remaining power.
Rugged Carrying Case - The HI98196 meter, probe and supplied accessories are provided in a protective carrying case with formed compartments to help secure the components during transport and storage.
On-screen features
Setup Screen - The setup menu provides configurable options for instrument operation, including date, time, temperature units and other measurement and display settings.
Guided Calibration - The meter provides on-screen guidance for calibration of the installed measurement sensors. This helps simplify routine calibration in the laboratory or field.
HI7698196 multiparameter probe
The HI7698196 is the digital multiparameter probe designed for use with the HI98196 portable meter. It accommodates the sensors required for pH/ORP and dissolved oxygen measurements and incorporates temperature measurement. Sensors are recognized automatically when connected, helping simplify setup and sensor replacement.
The probe is designed for field use and is available with different cable lengths for measurements at varying depths or distances from the meter. Its waterproof construction allows it to remain immersed during water-quality monitoring.
Color-Coded, Field-Replaceable Sensors
HI7698194-1 pH/ORP Sensor - Combination sensor for measurement of pH and oxidation-reduction potential.
HI7698194-2 Dissolved Oxygen Sensor - Galvanic dissolved oxygen sensor for measurement of dissolved oxygen concentration and percent saturation.
Quick Connect - The probe uses a waterproof Quick Connect connection to simplify attachment and removal from the meter.
Calibration Accessories - Calibration accessories help support regular sensor calibration and maintenance in the field or laboratory.
Rugged Carrying Case - The carrying case provides organized storage and protection for the meter, probe, sensors and supplied accessories.
Technical Q&A
What does the Hanna HI98196 measure?
The HI98196 measures pH/mV, ORP, dissolved oxygen, atmospheric pressure and temperature. It combines these measurements in one portable waterproof system using the HI7698196 digital multiparameter probe.
Does the HI98196 measure conductivity, TDS or salinity?
No. The HI98196 is configured for pH/ORP, dissolved oxygen, atmospheric pressure and temperature. Users who also require conductivity-related measurements should select a Hanna multiparameter model specifically equipped with an EC sensor.
What is ORP in water testing?
ORP stands for oxidation-reduction potential and is measured in millivolts. It indicates the tendency of a solution to participate in oxidation or reduction reactions and can provide useful information about chemical conditions in water and treatment processes.
Why is atmospheric pressure measured with dissolved oxygen?
Dissolved oxygen measurements are affected by atmospheric pressure. The HI98196 includes a built-in barometer so pressure can be taken into account when determining dissolved oxygen values, improving measurement consistency under changing environmental conditions.
Why is temperature important when measuring water quality?
Temperature can influence both water chemistry and sensor response. The HI98196 includes temperature measurement so temperature can be monitored alongside the other parameters and used for compensation where required.
Can the HI98196 be used for both field and laboratory measurements?
Yes. The portable meter is housed in an IP67-rated enclosure, while the probe is rated IP68 for continuous immersion. Its waterproof construction, replaceable sensors, data logging and carrying case make it suitable for field measurements while retaining the calibration, GLP and data-management functions useful in laboratory work.
How much data can the HI98196 store?
The meter can store up to 45,000 continuous or log-on-demand samples. This allows users to build measurement records, review changes over time and transfer logged results to a computer.
Can data from the HI98196 be transferred to a computer?
Yes. Logged measurements can be transferred through the meter's USB connection using compatible Hanna software, allowing results to be archived and reviewed electronically.
Are the sensors replaceable in the field?
Yes. The HI7698196 probe uses color-coded, screw-type replaceable sensors. The HI98196 configuration uses the HI7698194-1 pH/ORP sensor and the HI7698194-2 galvanic dissolved oxygen sensor.
How does automatic sensor recognition help the user?
The probe and meter recognize the installed sensors automatically. Only parameters associated with connected sensors are displayed and made available for configuration, which simplifies setup and helps reduce configuration errors.
Application Q&A
When is multiparameter water-quality monitoring useful?
Multiparameter monitoring is useful when several related water-quality conditions need to be assessed at the same location. Measuring pH, ORP, dissolved oxygen and temperature together can provide a more complete view of changing water conditions than measuring a single parameter alone.
When is data logging especially valuable?
Data logging is useful when changes need to be documented over time rather than evaluated from a single spot measurement. Logged records can support trend analysis, comparison between sampling locations, investigation of changing conditions and documentation of field or laboratory measurements.
What is the advantage of using one multiparameter probe?
A multiparameter probe allows several important water-quality measurements to be collected through one portable system. This can simplify field setup, reduce the number of separate instruments that must be carried and help keep related measurements together in the same data record.
Shipping calculated at checkout.
Returns accepted within 30 days for eligible items.
Warranty handled by manufacturer.
Some products may ship directly from U.S., Canadian, or international suppliers. Shipping |
Returns
Automatic at 1, 2 or 3 points with automatic recognition of 5 standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) and 1 custom buffer
ORP Range
±2000.0 mV
ORP Resolution
0.1 mV
ORP Accuracy
±1.0 mV
ORP Calibration
Automatic at 1 custom point (relative mV)
Dissolved Oxygen Range
0.0 to 500.0% saturation; 0.00 to 50.00 ppm (mg/L)
DO Resolution
0.1%; 0.01 ppm (mg/L)
DO Accuracy
0.0 to 300.0%: ±1.5% of reading or ±1.0%, whichever is greater;
300.0 to 500.0%: ±3% of reading;
0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater;
30.00 to 50.00 ppm (mg/L): ±3% of reading
DO Calibration
Automatic at 1 or 2 points at 0% and 100%, or 1 custom point
Atmospheric Pressure Range
450.0 to 850.0 mmHg;
17.72 to 33.46 inHg;
600.0 to 1133.2 mbar;
8.702 to 16.436 psi;
0.5921 to 1.1184 atm;
60.00 to 113.32 kPa
±3.0 mmHg within ±15 °C from calibration temperature
Atmospheric Pressure Calibration
Automatic at 1 custom point
Temperature Range
−5.00 to 55.00 °C;
23.00 to 131.00 °F;
268.15 to 328.15 K
Temperature Resolution
0.01 °C; 0.01 °F; 0.01 K
Temperature Accuracy
±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration
Automatic at 1 custom point
Additional Specifications
Maximum Probe Immersion
20 m (66 ft)
Temperature Compensation
Automatic from −5 to 55 °C (23 to 131 °F)
Logging Memory
45,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval
1 second to 3 hours
PC Connectivity
USB with HI9298194 Hanna PC software
Environment
0 to 50 °C (32 to 122 °F); RH 100%
Waterproof Protection
IP67
Battery Type
Four 1.5 V AA alkaline batteries
Battery Life
Approximately 360 hours of continuous use without backlight; approximately 50 hours with backlight
Dimensions / Weight
185 × 93 × 35.2 mm (7.3 × 3.6 × 1.4 in.) / 400 g (14.2 oz.)
Ordering Information
HI98196 is supplied with HI7698196 multiparameter probe, HI7698194-1 pH/ORP sensor, HI7698194-2 dissolved oxygen sensor, probe maintenance kit, calibration beaker, Hanna PC software, micro USB cable, four 1.5 V AA batteries, instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert.
Our parent site geneq.com works by quote requests, so we can offer a unique price per any combination of items you choose, and the best shipping company/route for weighty items. We distribute the biggest names in the industry since 1972!