- 12 months limited warranty
- Can measure and record temperatures as low as -100 °C (-148 °F)
- Audible and LED Alarm Indicators
- On-Screen Min, Max & Average Statistics
MadgeTech High Temperature Data Loggers for Application-Based Model Selection
This series is designed for cold-chain documentation, environmental monitoring, museums, storage rooms, facilities management, and validation workflows, where the right choice often depends on differences in sensor type, communication method, channel configuration, and deployment conditions.
This stainless steel device is submersible, can withstand temperatures up to 140 °C (284 °F), and has an accuracy of +/-0.1 °C (0.18 °F). With the HiTemp140’s standard calibration, an accuracy of +/-0.1 °C (0.18 °F) can be achieved over a wide temperature range.
Applications
• Autoclave Verification
• Implement HACCP Programs
• Food Preparation and Processing
• Environmental Studies
• Well Monitoring
• Dishwasher Testing
• Pasteurization
HiTemp140 high-temperature datalogger
The HiTemp140 high-temperature datalogger can withstand temperatures ranging from -40 °C to +140 °C (-40 °F to +284 °F), but is capable of measuring extended temperatures up to 260 °C (500 °F) (probe dependent). With a storage capacity of up to 65,536 time and date stamped readings, the HiTemp140 can be programmed for immediate start or delayed start up to 18 months in advance. The HiTemp140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units. Body of data logger cannot exceed 140 °C (284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.
HiTemp140 high-temperature datalogger -Features
• ±0.1 °C (0.18 °F) Accuracy • Operates Up To 140 °C (284 °F)
• Submersible (IP68) • User-Replaceable Battery
• Rugged
• Programmable start time
• Programmable stop time
• Engraved Label
• Probe Lengths Up To 7 inches
• Battery Life Indicator
Related Products
For complementary data logging solutions, you might consider the Compact Rugged Temperature Data Loggers for flexible lab or field use, the Valor 2000 Waterproof Precision Balances for accurate measurements in wet environments, or the High-Capacity Precision Balances for demanding industrial weighing applications.
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment Using the MadgeTech Software, starting, stopping and downloading the HiTemp140 is simple and easy. To use, simply place the HiTemp140 in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.
Product Q&A
What temperature range can the HiTemp140 measure?
The HiTemp140 operates safely up to 140 °C (284 °F), but with compatible probes and MadgeTech thermal barriers, it can measure temperatures up to 260 °C (500 °F).
Is the HiTemp140 submersible?
Yes, the device is IP68-rated, making it fully submersible for harsh environments, including autoclave and dishwasher applications.
How many readings can the HiTemp140 store?
The HiTemp140 can store up to 65,536 time- and date-stamped readings, allowing long-term monitoring and data logging.
How do I start or schedule the HiTemp140?
Using MadgeTech 4 Software, you can set an immediate start or schedule a delayed start up to 18 months in advance. Both start and stop times are programmable.
Can I analyze the recorded data easily?
Yes, MadgeTech 4 Software provides graphical, tabular, and summary views. Data can also be exported to Excel® and displayed in customizable engineering units such as °C, °F, K, or °R.
How is the HiTemp140 powered?
The unit uses a user-replaceable battery and includes a battery life indicator for easy maintenance.
QUICK TIP:
Downloading data from a data logger
• Place the logger into the docking station.
• Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
• Once the data logger is stopped, with the logger highlighted, click “Download”
. You will be prompted to name your report.
• Downloading will offload and save all the recorded data to the PC. Learn more in the Instruction Manual / Quick Start Guide
Wireless Vaccine Temperature Monitoring System - Specifications
| TEMPERATURE | |
| Internal Channel Temperature Range | -20 °C to +60 °C (-4 °F to +140 °F) |
| Resolution | 0.1 °C (0.18 °F) |
| Calibrated Accuracy | ±0.5 °C/± 0.18 °F (0 °C to +55 °C/32 °F to 131 °F ) |
| Response Time | 10 minutes free air |
| REMOTE CHANNEL | |
| Thermocouple Connection | Female subminiature (SMP) |
| Cold Junction Compensation | Automatic, based on internal channel |
| Max. Thermocouple Resistance | 100 Ω |
| Thermocouple K | Thermocouple Range: -100 °C to +80 °C (-148 °F to +176 °F) Glycol Bottle Range: -50 °C to +80 °C (-58 °F to +176 °F) Resolution: 0.1 °C Accuracy: ±0.5 °C |
| Response Time | τ = 2 minutes to 63% of change |
| WIRELESS | |
| RF Frequency | 2.45 GHz IEEE 802.15.4 ultra-low-power wireless transceiver with fully bi-directional communication |
| Band | ISM band 2.405-2.475 GHz |
| Maximum Output Power | +0 dBm typical |
| Receiver Sensitivity (RFC1000) | -95 dBm typical |
| Transmission Distance (to data loggers) | RFC1000, RFC1000-CE & RFC1000-IP69K 2,000 ft max. outdoors - line of sight unobstructed 500 ft max. indoors - typical urban environment |
| Transmission Distance (to other RFC1000’s) | RFC1000 4,000 ft max. outdoors - line of sight unobstructed 1,000 ft max. indoors - typical urban environment RFC1000-CE 2,500 ft max. outdoors - line of sight unobstructed 700 ft max. indoors - typical urban environment RFC1000-IP69K 4,000 ft max. outdoors - line of sight unobstructed 1,000 ft max. indoors - typical urban environment |
| GENERAL | |
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Memory | 16,128 per channel |
| LED Functionality | Green LED blinks every 5 seconds to indicate the unit is logging Blue LED blinks every 15 seconds to indicate the unit is in wireless mode Red LED blinks every 1 second to indicate an alarm condition |
| Wrap Around | Yes |
| Start Modes | Immediate and delay start |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within the device |
| Battery Type | 9 V lithium or alkaline battery included; user-replaceable with any 9 V battery |
| Battery Life | 3 years typical at 1-minute reading rate |
| Data Format | For Display: °C or °F For Software: Date and time-stamped °C, K, °F, or °R |
| Time Accuracy | ± 1 minute/month |
| Computer Interface | USB to mini USB, 250,000 baud for standalone operation or RFC1000 required for wireless operation |
| Operating System Compatibility | Windows XP SP3 or later |
| Software Compatibility | Standard Software version 4.1.0.0 or later Secure Software version 4.1.3.0 or later |
| Operating Environment | -20 ºC to +60 ºC (-4 ºF to +140 ºF), 0 %RH to 95 %RH non-condensing |
| Dimensions | 3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) Data logger only |
| Material | ABS Plastic |
| Weight | 4.5 oz (129 g) |
| Approvals | US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE) |
| Alarm | User-configurable high and low audible, on-screen, email, and text (SMS) alarms. Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user-specified time duration of data. |
| Audible Alarm Functionality | 1 Beep per second for reading alarm above/below the threshold |
Product Models
| Product | Price | ||
|---|---|---|---|
|
Wireless Vaccine temperature monitoring system - VTMS (250ml) |
$USD 394.00
|
|
|
Wireless Vaccine temperature monitoring system - VTMS (30ml) |
$USD 394.00
|
|
|
Wireless Vaccine temperature monitoring system - VTMS (No Glycol Bottle) |
$USD 374.00
|
|
|
Wireless Vaccine temperature monitoring system - VTMS (60ml) |
$USD 394.00
|
|
Need larger scale equipment for a bigger project?
Our parent site geneq.com works by quote requests, so we can offer a unique price per any combination of items you choose, and the best shipping company/route for weighty items. We distribute the biggest names in the industry since 1972!